For a single-phase-to-earth fault occurring on the medium-voltage network, the first few seconds are critical. Efficient neutral earthing equipment will be able to convert the dangerous arc fault into a low current that dissipates naturally without any external intervention. This is achieved by the arc suppression coil. This explains how our Bias magnetic type Arc Suppression Coil works, what it includes, and how to choose the right one for your grid.
The Bias magnetic type Arc Suppression Coil is intended for medium voltage distribution networks (from 6 kV to 66 kV). While traditional arc suppression coils use the variation of tap positions by changing the number of winding turns, our design allows varying the magnetic bias in the magnetic core of the coil. It makes it possible to regulate our Arc Suppression Coil continuously over the whole range. A Magnetic Bias Arc Suppression Coil of this type can be adjusted from 0 to 100 per cent of its nominal current.
Below is information about our bias magnetic type arc suppression coil and control unit.
It is worth noting that each Magnetic Bias Arc Suppression Coil is optimised according to your capacitive current. Provide your data before placing an order!
The key advantage is tuning stability. A Continuously Adjustable Arc Suppression Coil never moves directly to another tap position; it selects the correct position and stays there, making it possible to keep the residual current down during the fault occurrence. As there is no need for moving taps in the Bias magnetic type Arc Suppression Coil, it has fewer mechanical parts subject to wear.
A Continuously Adjustable Arc Suppression Coil provides stable protection for operators with minimum manual actions needed.
We not only provide the coil itself. A typical package includes a Bias magnetic type Arc Suppression Coil body, a controller, a damping resistor and a feeder line selector module that identifies the faulty line. The controller features an internal printer for storing information about faults and remote signalling via conventional ports. In case there is no neutral point in your grid, we can supply you with a grounding transformer to create one. Every Magnetic Bias Arc Suppression Coil is shipped together with its dedicated controller. Please contact our specialists to know the exact package contents.
Electric utilities use a Bias magnetic type Arc Suppression Coil in 6 kV to 66 kV grids, particularly those that feature overhead lines and cables of relatively large lengths and frequently experience ground faults. In addition, this coil is suitable for industrial facilities, mines, harbours, and power plants, which have to operate with a single ground fault. In case of frequent changes in a power grid, a Magnetic Bias Arc Suppression Coil would be a reasonable choice since its tuning corresponds to the grid itself.
It all starts with a good coil. Our team tests each coil at the manufacturing plant before supporting you at the site. We will assist with checking the wiring, configuration of the controller, measuring the capacitive current, and functional testing of the Bias magnetic type Arc Suppression Coil. In addition, our engineers will perform line selection and communication checks to ensure proper communication with your control centre. Staff training can be provided as well as the assessment of the results of the commissioning of the unit. The same goes for the Continuously Adjustable Arc Suppression Coil: We will check the tuning accuracy during commissioning.
We are the producer of neutral earthing equipment, reactors, and resistors based in Baoding, Hebei Province, China. The bias magnetic type Arc Suppression Coil is equipped with a dependable controller, excellent electrical isolation, and user-friendly touch screen control. In addition, we provide the turn adjustment coils, thus offering you an opportunity to consider both options. Each Magnetic Bias Arc Suppression Coil is accompanied by the drawings and technical manual. One company will take care of the design, supply, and service.
A turn-adjustable coil changes its setting by switching taps in steps. A Bias magnetic type Arc Suppression Coil changes the magnetic bias in the core, so it tunes smoothly and has no tap changer to wear out.
The response time of a Magnetic Bias Arc Suppression Coil is under 20 ms. The controller measures the new capacitive current, and the coil follows right away.
If feeders are added, cut, or switched often, the capacitive current keeps moving. In that case, a Continuously Adjustable Arc Suppression Coil keeps the network close to ideal tuning without manual steps.
Very little. Check the controller screen, clean the enclosure, test communication, and review fault records now and then. Without a tap changer, a Bias magnetic type Arc Suppression Coil has fewer parts to service.
Please share the system voltage, busbar layout, estimated capacitive current, feeder count, and site conditions. With that, we can size a Bias magnetic type Arc Suppression Coil that fits your network.