One fault on the ring main can turn off the entire neighbourhood within seconds. That is what buyers look for in Metal Switchgear and RMU: The appropriate panel will isolate the fault and restore the power supply.
Metal Switchgear designs and manufactures panels and ring main units according to your single-line diagram and delivers them to you anywhere in the world.
As an expert in Metal Clad Switchgear, we ensure that each compartment is well protected, serviced and operable.
Our range of Metal Switchgear and RMU includes primary panels, secondary panels and ring main units. All of them are custom manufactured.
The primary switchgear is the heart of the substation where feeders are controlled. Metal Switchgear provides complete solutions based on vacuum circuit breakers (VCB) per panel.
Get Metal Switchgear and RMU partner who helps you to determine ratings and the order of panels.
Secondary Metal Switchgear and RMUs supply transformers and downstream loads. Air Insulated Panels are simple and easy to inspect. Gas insulated panels are small and sealed; hence they are ideal in compact rooms with poor air conditions.
Both types of panels can be made as Metal Clad Switchgear where the busbars, breakers and cables are housed in separate compartments within the earthed panel.
Some of the RMUs found in our catalogue include outdoor gas-insulated ring main units, enclosed units, kiosk-type units and the RMR-12/24N SF6 type.
Voltage ratings of 12/24kV and 40.5 kV gas-insulated are available for the gas-insulated RMUs; thus, one Metal Switchgear and RMU supplier will serve various sites.
Five criteria determine any Metal Switchgear or RMU order:
| Parameter | What we confirm |
|---|---|
| Voltage | Rated voltage, such as 12kV, 24 kV, or 40.5kV |
| Current | Busbar and feeder rated current |
| Short-circuit rating | Fault level and duration your network needs |
| Insulation | Air, gas or solid |
| Protection | Relays, fuses and earthing arrangement |
The ratings will be matched to your system studies; hence, no panel will be oversized or undersized.
Any Metal Clad Switchgear Manufacturer should be able to match these criteria to your system studies.
Safety is a priority when designing Metal Switchgear and RMU. Some features of the product line include:
Sealed enclosures which keep the live parts protected from dust and humidity, and proper labelling assists safe operation.
Compartment separation is the defining feature of Metal Clad Switchgear.
Wherever medium voltage electricity is distributed, Metal Switchgear and RMU is a good solution:
Low maintenance units are required in rural areas, while compact ones in the city.
Every enclosure from a street kiosk to a plant room requires a particular Metal Switchgear and RMU arrangement.
It all begins with your single-line diagram. This is what a custom order entails:
The Metal Clad Switchgear partner who works on your diagram will save you money in terms of on-site modification.
Metal switchgear and RMU layouts can have special busbars, cable entry and metering sections.
Inform us regarding cable entry, metering and enclosures early enough for the first drawings to be correct.
Once manufactured, each completed panel will undergo rigorous testing prior to delivery. Quality is our first commitment at Metal Switchgear and RMU. Typical tests that we conduct include:
We provide test reports and approved drawings with every Metal Clad Switchgear order.
Weifan Electrical Technology Co., Ltd. has been manufacturing electrical power equipment for over 20 years and delivering to over 80 countries. We consider each of our Metal Switchgear and RMU projects individually, rather than just packing and shipping an item.
When evaluating Metal Switchgear and RMU manufacturers, you should consider clarity of drawings and quick response times.
In addition to our Metal Switchgear and RMU products, we manufacture transformers, power resistors, reactors and neutral earthing units, meaning that there is no need to deal with several different suppliers.
Send us your single-line diagram, voltage requirements, and installation site, and we will provide you with the best Metal Switchgear and RMU solution.
Air-insulated panels suit roomy, clean indoor sites and are easy to inspect. Gas-insulated panels save space and cope with humidity and dust. Solid-insulated units are compact with low upkeep. Share your room size and environment, and we will recommend the best fit.
Take the maximum fault level at the installation point from your network study, then choose a rating above it, with the right duration. Your utility can supply fault data if you do not have it. Send us the figures, and we will confirm.
Yes. Tell us your relays, fuses, CT and VT needs, and interlocking rules. We build the panel around your scheme and show it on the drawings for approval.
Sealed gas-insulated or solid-insulated units resist moisture, dust and salt air best. Add suitable enclosure protection, heaters and coastal coatings where needed. Describe your site, and we will advise.
Plan regular visual checks, cleaning, tightness checks, operating tests and protection testing. Sealed and solid-insulated designs need less routine work. Follow the maker’s maintenance guide.