Metal Switchgear and RMU

Metal Switchgear and RMU

Metal Clad Switchgear and RMU Manufacturer for Medium-Voltage Distribution

One fault on the ring main can turn off the entire neighbourhood within seconds. That is what buyers look for in Metal Switchgear and RMU: The appropriate panel will isolate the fault and restore the power supply.

Metal Switchgear designs and manufactures panels and ring main units according to your single-line diagram and delivers them to you anywhere in the world.

As an expert in Metal Clad Switchgear, we ensure that each compartment is well protected, serviced and operable.


Our Switchgear and RMU Range

Our range of Metal Switchgear and RMU includes primary panels, secondary panels and ring main units. All of them are custom manufactured.

Medium Voltage Switchgear (Primary)

The primary switchgear is the heart of the substation where feeders are controlled. Metal Switchgear provides complete solutions based on vacuum circuit breakers (VCB) per panel.

Get Metal Switchgear and RMU partner who helps you to determine ratings and the order of panels.

Air and Gas Insulated Switchgear (Secondary)

Secondary Metal Switchgear and RMUs supply transformers and downstream loads. Air Insulated Panels are simple and easy to inspect. Gas insulated panels are small and sealed; hence they are ideal in compact rooms with poor air conditions.

Both types of panels can be made as Metal Clad Switchgear where the busbars, breakers and cables are housed in separate compartments within the earthed panel.

Solid, Indoor and Outdoor Ring Main Units

  • Solid: Compact units with solid insulation for low maintenance
  • Indoor: Ring main unit like the 11kV/ 12kV CCV indoor ring main unit
  • Outdoor: Kiosk, enclosed and gas-insulated Ring Main Units (RMUs)

Some of the RMUs found in our catalogue include outdoor gas-insulated ring main units, enclosed units, kiosk-type units and the RMR-12/24N SF6 type.

Voltage ratings of 12/24kV and 40.5 kV gas-insulated are available for the gas-insulated RMUs; thus, one Metal Switchgear and RMU supplier will serve various sites.


Technical Specifications

Five criteria determine any Metal Switchgear or RMU order:

Parameter What we confirm
Voltage Rated voltage, such as 12kV, 24 kV, or 40.5kV
Current Busbar and feeder rated current
Short-circuit rating Fault level and duration your network needs
Insulation Air, gas or solid
Protection Relays, fuses and earthing arrangement

The ratings will be matched to your system studies; hence, no panel will be oversized or undersized.

Any Metal Clad Switchgear Manufacturer should be able to match these criteria to your system studies.


Key Features and Safety Design

Safety is a priority when designing Metal Switchgear and RMU. Some features of the product line include:

  • Earthed metal compartments that separate the busbars, switching apparatus and cables
  • Mechanical and electrical interlocks which prevent faulty switching
  • Visible earthing and position indication
  • Option of pressure relief or arc containment for the operator’s safety
  • Small footprint suitable for tight enclosures and kiosks

Sealed enclosures which keep the live parts protected from dust and humidity, and proper labelling assists safe operation.

Compartment separation is the defining feature of Metal Clad Switchgear.


Applications

Wherever medium voltage electricity is distributed, Metal Switchgear and RMU is a good solution:

  • Substations and ring networks of utilities
  • Residences and offices
  • Industries, mines and ports
  • Collector stations of solar and wind power plants
  • Aircraft, railway and telecommunication facilities

Low maintenance units are required in rural areas, while compact ones in the city.

Every enclosure from a street kiosk to a plant room requires a particular Metal Switchgear and RMU arrangement.


Customisation to Your Single-Line Diagram

It all begins with your single-line diagram. This is what a custom order entails:

  1. Provide your diagram and loading data.
  2. Panel layouts, rating and protection proposal will be provided.
  3. Approval will be provided by you of the drawings.
  4. Assembly, testing, and inspection will follow.
  5. Documentation and customs clearance during shipping will be provided.

The Metal Clad Switchgear partner who works on your diagram will save you money in terms of on-site modification.

Metal switchgear and RMU layouts can have special busbars, cable entry and metering sections.

Inform us regarding cable entry, metering and enclosures early enough for the first drawings to be correct.


Testing and Quality

Once manufactured, each completed panel will undergo rigorous testing prior to delivery. Quality is our first commitment at Metal Switchgear and RMU. Typical tests that we conduct include:

  • Power frequency withstand test
  • Main circuit resistance test
  • Mechanical operation and interlocking test
  • Protection and control wiring test

We provide test reports and approved drawings with every Metal Clad Switchgear order.


Why Choose Us

Weifan Electrical Technology Co., Ltd. has been manufacturing electrical power equipment for over 20 years and delivering to over 80 countries. We consider each of our Metal Switchgear and RMU projects individually, rather than just packing and shipping an item.

  • Professional engineers who will examine your single-line diagram before manufacturing
  • Strict quality control after manufacturing
  • International delivery, customs clearance, and storage services
  • Online customer support 24/7

When evaluating Metal Switchgear and RMU manufacturers, you should consider clarity of drawings and quick response times.

In addition to our Metal Switchgear and RMU products, we manufacture transformers, power resistors, reactors and neutral earthing units, meaning that there is no need to deal with several different suppliers.

Send us your single-line diagram, voltage requirements, and installation site, and we will provide you with the best Metal Switchgear and RMU solution.


Frequently Asked Questions

1. How do I choose between AIS, GIS and solid-insulated switchgear?

Air-insulated panels suit roomy, clean indoor sites and are easy to inspect. Gas-insulated panels save space and cope with humidity and dust. Solid-insulated units are compact with low upkeep. Share your room size and environment, and we will recommend the best fit.

2. How do I confirm the short-circuit rating I need?

Take the maximum fault level at the installation point from your network study, then choose a rating above it, with the right duration. Your utility can supply fault data if you do not have it. Send us the figures, and we will confirm.

3. Can the panel match my protection scheme?

Yes. Tell us your relays, fuses, CT and VT needs, and interlocking rules. We build the panel around your scheme and show it on the drawings for approval.

4. What suits a humid, dusty or coastal site?

Sealed gas-insulated or solid-insulated units resist moisture, dust and salt air best. Add suitable enclosure protection, heaters and coastal coatings where needed. Describe your site, and we will advise.

5. How is the switchgear maintained over its life?

Plan regular visual checks, cleaning, tightness checks, operating tests and protection testing. Sealed and solid-insulated designs need less routine work. Follow the maker’s maintenance guide.

WhatsApp WhatsApp QR Code

Get in touch


    (jpg、jpeg、png、pdf、doc、docx、xls、xlsx、csv、txt)